›› 2015, Vol. 10 ›› Issue (5): 105-109.

• 论文 • 上一篇    下一篇

Determination of the Total Content of Iodine in Wuhai Yingliu Pill and Neixiao Luoli Pill and Related Drugs within Them by UV-Vis spectroscopy

Haiyan Huang, Xizhe Li, Zhong Yuan*   

  1. School of Traditional Chinese Materia Medica, Shenyang Pharmaceutical University, Shenyang 110016, People’s Republic of China
  • 收稿日期:2015-01-04 修回日期:2015-07-12 出版日期:2015-10-20 发布日期:2015-10-20

Determination of the Total Content of Iodine in Wuhai Yingliu Pill and Neixiao Luoli Pill and Related Drugs within Them by UV-Vis spectroscopy

Haiyan Huang, Xizhe Li, Zhong Yuan*   

  1. School of Traditional Chinese Materia Medica, Shenyang Pharmaceutical University, Shenyang 110016, People’s Republic of China
  • Received:2015-01-04 Revised:2015-07-12 Online:2015-10-20 Published:2015-10-20
  • Contact: Zhong Yuan

摘要: A method for determination of total content of iodine in Wuhai Yingliu Pill and Neixiao Luoli Pill was developed by UV-Vis spectroscopy at 420 nm wavelength. Firstly, all the sample solutions in this work and the mixture of K2CO3-ZnSO4 and KClO3- NaCl were heated in dry bath at 300°C for about 3 h; Then the supernatant was collected after dissolving with water; At last, the absorbance was measured based on the catalytic of iodine in arsenic cerium oxide reduction reaction. Using this method, 23 samples were analyzed. A good linear regression relationship was obtained over the range of 0-1200 μg/L (r=0.9989) for standard solutions, the recovery rate was 96.54%, RSD=3.02% (n=9). The method was successfully applied to analyze these two Chinese patent medicines as a quantity control for clinical use in different types of thyroid disease.

Abstract: A method for determination of total content of iodine in Wuhai Yingliu Pill and Neixiao Luoli Pill was developed by UV-Vis spectroscopy at 420 nm wavelength. Firstly, all the sample solutions in this work and the mixture of K2CO3-ZnSO4 and KClO3- NaCl were heated in dry bath at 300°C for about 3 h; Then the supernatant was collected after dissolving with water; At last, the absorbance was measured based on the catalytic of iodine in arsenic cerium oxide reduction reaction. Using this method, 23 samples were analyzed. A good linear regression relationship was obtained over the range of 0-1200 μg/L (r=0.9989) for standard solutions, the recovery rate was 96.54%, RSD=3.02% (n=9). The method was successfully applied to analyze these two Chinese patent medicines as a quantity control for clinical use in different types of thyroid disease.

Key words: total content of iodine, Wuhai Yingliu Pill, Neixiao Luoli Pill, related drugs, UV-Vis spectroscopy